5300VA SINEWAVE UPS
The UPS-3PH-5300VA-115VAC is a 3 Phase 115V/60Hz input UPS with Active Power Factor Correction (greater than 0.99). Compact design provides 4,000 watts in a 5U high, 19 inch rack mountable package which weighs less than 85lbs (without batteries). This rugged UPS was specifically intended for use in a shipboard/submarine environment and has been designed to meet the following standards:
MIL-STD-1399
MIL-STD-461F
MIL-STD-810G
Available customizable features include:
External Battery Backup Rack Assembly
Chassis Guide Rails
Single Phase Input
3 Phase 440VAC Input
250VDC Input
Isolated Aux. DC Output
3 Phase Output
Click on data sheet below for additional information:
Data Sheet: UPS-3PH-5300VA-115VAC
SNS-5600S Air Cooled 5600 Watt, 270Volt/20.7Amp, Radar Transmitter Power Supply. 5600 Watts in 6.8"x8.13"x15.00" Size!
3 Phase 220V/60Hz and 380V/50Hz Input with Active power Factor Correction
(Greater Than 0.99)
Meets MIL-STD-1399, Section 300A (Type I) for the Voltage Ranges Specified
Input Current THD not Exceeding 4%.
Patent Pending Topological Approach Resulting in Cancellation of all Harmonic
Power Line Frequency on the Output Ripple Without the need for additional large output LC filter.
True Hot Swap with Floating ELCON Mini-Drawer Connector.
N+1 Redundant with Internal Oring Diodes.
Active Zero Wire Current Share Allowing for Redundant Modules to Share With in
10% of Each Other.
Output Test Points on Front Panel
LED Display for Output, Temp., Over Current and Fan Status
Ruggedized Mechanical Design Meeting MIL-STD-810F, Method 514.5, Category
24, Procedure 1.
Product Data Sheet: SNS-5600S
"VPX" Power Supply Model: VPX-700-P
700 Watts in a 6U x 5HP(1" pitch) x 160mm package. VITA 62 compliant with conduction cooling scheme via wedge lock retainers. Standard features include; built in Oring FET's/Diodes, fault monitoring, AC input with Active Power Factor Correction and an I2C interface for status and control. Some available options are:
Ruggedization
Machined Alignment Keys
Increased Energy Storage
Custom Input/Output Configurations
Conformal Coating with Parylene
Removal of EEPROM
Click on data sheet below for additional information:
Product Data Sheet: VPX-700-P
***Visit our VPX Product Page***
Liquid Cooled
FEATURES: Liquid Cooled 60/40 Ethylene Glycol-Water Mix coolant with attached Cold Plate.
Operating Temperature: -40C to +85C.
2000 Watts in 11.81"x 12.40"x 4.72" Size!
3 Phase input 480V/60Hz.
+28VDC/70A Output.
LED display for Input/Output status.
This unit is fully ruggedized and Parylene coated to withstand harsh environmental conditions. Designed for use in Military Mobile applications.
Certified to meet:
Environmental requirements per MIL-STD-810F, including operational salt fog, and EMI per Mil-Std-461.
Product Data Sheet: LC-2000S
Baseplate Cooled From -40°C to +100°C
Compact design provides 1kW of output power in only a 3" x 6" x 10" package. This supply is fully ruggedized and utilizes Parylene Coating to help withstand extreme harsh environmental conditions. It was designed for use in a Military Mobile Application for the US Marine Corp. Some key features are as follows:
Designed to Meet MIL-STD-704F
Designed to Meet MIL-STD-810G
Designed to Meet MIL-STD-461E
Active Power Factor Correction (>0.95 Lagging)
Greater than 89% Efficient
N+1 Redundant with Internal Oring FET
Custom Input/Output Configurations Available
Click on data sheet below for additional information:
Product Data Sheet: SNS-GTR-1000S-28
3-Phase Transformer Rectifier Units (TRUs)
Using our patent pending Passive Harmonic Attenuator (Ref. Patent# 62/220,612), our TRUs provide extremely low harmonic current limits, have built in AC input inrush current limiting and output current limiting. Some additional features include:
Power Levels from 100W to 10kW
60Hz and 400Hz Versions
Options for Forced Air or Conduction Cooling
Custom Input/Output Configurations
Conformal Coating (Acrylic or Parylene)
Product Data Sheet: TRU Series
| | |