|
![]() | ||
What's New ![]() 5300VA SINEWAVE UPS The UPS-3PH-5300VA-115VAC is a 3 Phase 115V/60Hz input UPS with Active Power Factor Correction (greater than 0.99). Compact design provides 4,000 watts in a 5U high, 19 inch rack mountable package which weighs less than 85lbs (without batteries). This rugged UPS was specifically intended for use in a shipboard/submarine environment and has been designed to meet the following standards: Available customizable features include: Click on data sheet below for additional information: Data Sheet: UPS-3PH-5300VA-115VAC 5600 Watt, 270Volt/20.7Amp, Radar Transmitter Power Supply. 5600 Watts in 6.8"x8.13"x15.00" Size! 3 Phase 220V/60Hz and 380V/50Hz Input with Active power Factor Correction (Greater Than 0.99) Meets MIL-STD-1399, Section 300A (Type I) for the Voltage Ranges Specified Input Current THD not Exceeding 4%. Patent Pending Topological Approach Resulting in Cancellation of all Harmonic Power Line Frequency on the Output Ripple Without the need for additional large output LC filter. True Hot Swap with Floating ELCON Mini-Drawer Connector. N+1 Redundant with Internal Oring Diodes. Active Zero Wire Current Share Allowing for Redundant Modules to Share With in 10% of Each Other. Output Test Points on Front Panel LED Display for Output, Temp., Over Current and Fan Status Ruggedized Mechanical Design Meeting MIL-STD-810F, Method 514.5, Category 24, Procedure 1. Product Data Sheet: SNS-5600S
![]() Model: VPX-700-P 700 Watts in a 6U x 5HP(1" pitch) x 160mm package. VITA 62 compliant with conduction cooling scheme via wedge lock retainers. Standard features include; built in Oring FET's/Diodes, fault monitoring, AC input with Active Power Factor Correction and an I2C interface for status and control. Some available options are: Product Data Sheet: VPX-700-P VPX Product Page ![]() LC-2000S Liquid Cooled 60/40 Ethylene Glycol-Water Mix coolant with attached Cold Plate. Operating Temperature: -40C to +85C. 2000 Watts in 11.81"x 12.40"x 4.72" Size! 3 Phase input 480V/60Hz. +28VDC/70A Output. LED display for Input/Output status. Certified to meet: High Temperature per MIL-STD-810F, Method 501.4 Procedure I and II Low Temperature per MIL-STD-810F, Method 502.4 Procedure I and II Humidity per MIL-STD-810F, Method 507.4 Pressure Altitude per MIL-STD-810F, Method 500.4 Procedure I up to 40,000ft Non-operational Pressure Altitude per MIL-STD-810F, Method 500.4 Procedure II up to 10,000ft operational Fungus per MIL-STD-810F, Method 508.4 Sand and Dust per MIL-STD-810F, Method 510.4 Procedures I, II and III Operational Salt Fog per MIL-STD-810F, Method 509.4 Vibration per MIL-STD-810F, Method 514.5 Category 6, procedure I composite wheeled, and US highway truck Shock: +/-15g for 11ms, half sine, each direction, all 3 axes Bench Handling: MIL-STD-810F, Method 516.5, Procedure VI. EMI meets: RS103 (Army Ground) RE102(Navy Limits) CE102 CS101 (Army Ground) CS114 (Army Ground) CS115 (Army Ground) CS116 (Army Ground) Product Data Sheet: LC-2000S (TRUs) Product Data Sheet: TRU Series GAT-50W Conduction Cooled. ![]() Low Profile 5.0" x 4.25" x 0.85" Size. Operational Temperature -40 to 100 degrees C. Remote Sense Output Designed to meet the following specifications: High Temperature per MIL-STD-810F, Method 501.4 Procedure I and II Low Temperature per MIL-STD-810F, Method 502.4 Procedure I and II Humidity per MIL-STD-810F, Method 507.4(Non Operational) Pressure Altitude per MIL-STD-810F, Method 500.4 Procedure I up to 40,000ft Non-operational Pressure Altitude per MIL-STD-810F, Method 500.4 Procedure II up to 10,000ft operational Fungus per MIL-STD-810F, Method 508.4 Sand and Dust per MIL-STD-810F, Method 510.4 Procedures I, II and III Salt Fog per MIL-STD-810F, Method 509.4 Vibration per MIL-STD-810F, Method 514.5 Category 6, procedure I composite wheeled, and US highway truck Shock: +/-15g for 11ms, half sine, each direction, all 3 axes Bench Handling: MIL-STD-810F, Method 516.5, Procedure VI. Product Data Sheet: GAT-50W Inprocess Preview: GAT-50W |